Get a quote

Home / Products / Double Column

Double column solar carport

Two column lines support the roof like a portal frame. It takes the highest wind and snow loads with the lightest foundations, at the cost of columns between the rows.

Double column solar carport

Overview

Why choose this structure

  • Lower foundation moments than cantilever designs
  • Higher wind and snow capacity for the same steel
  • Allows larger roof depths and spans
  • Good choice where soil bearing capacity is low

Best for: High-wind and heavy-snow regions, large spans, poor soils.

Covers: 2 rows (columns at front and back) or 1 wide row. Typical dimensions: Roof depth 10–16 m; column spacing 6.0–10.0 m.

Double column solar carport – schematic side view

Specification

Typical configuration

Values below are typical. Every project is designed for its own site loads, module size and layout.

Structure materialHot-dip galvanized steel Q355 / S355, Zn-Al-Mg coated steel, or aluminium AL6005-T5
Design wind speedUp to about 60 m/s, designed to the site
Snow loadUp to about 1.4–2.0 kN/m², higher on request
Roof tilt0–15° typical (up to 30° on request)
Clear height2.2–3.0 m; higher for buses and trucks
Module layoutPortrait or landscape, framed modules of most sizes
ConnectionsBolted, no welding on site
FoundationsConcrete pad or pier with anchor bolts; ground screws on suitable soils
Design codesEN 1991 / EN 1993, ASCE 7, AS/NZS 1170, or the code you name
Warranty10 years on the structure; 25-year design life

Scope of supply

What is in the package

StructureColumns, beams, rafters, purlins / module rails, bracing
FixingsAnchor bolts, structural bolts, module clamps, earthing parts
OptionsGutter rails and edge gutters, LED lights, charger mounting plates, cable trays, signage
DocumentsLayout, structural calculation summary, shop and installation drawings, part marks, packing list

Standard models

Model range

One bay of each model. Projects repeat bays along the row. Module count based on typical 580 W modules (2278 × 1134 mm); other module sizes on request.

ModelCovers per bayBay size (W × D)Modules per baykWp per bayNote
SPS-D44 cars (2 + 2)5.0 × 10.6 m169.3–
SPS-D66 cars (3 + 3)7.5 × 11.5 m3017.4–
SPS-D99 cars (3 + 3 + 3)7.5 × 16.0 m4224.4Wide roof

Components

What is in the structure

Every part is cut, drilled and coated in the factory and marked by bay, so installation needs no welding or cutting on site. See all components and accessories.

ColumnsH-section or box section, with welded base plate
Main beams and knee bracesH-section or box section, bolted end plates
Purlins / module railsCold-formed C or Z sections, pre-punched to the module layout
Module clampsAluminium mid and end clamps, stainless steel bolts
Gutter rails (waterproof types)Aluminium or coated steel channels under the module joints
Foundation partsAnchor bolts with setting templates, or ground screws
Exploded view of solar carport components

Installation

Six steps on site

Foundations

Cast concrete pads or piers with anchor bolts set by template, or drive ground screws.

Columns

Lift columns onto the anchor bolts, level with nuts, and tighten.

Beams and braces

Bolt main beams and knee braces to the columns; check alignment along the row.

Purlins

Fix the pre-punched purlins or module rails; add gutter rails for waterproof types.

Modules

Clamp the modules row by row to the torque in the manual.

Earthing and checks

Connect earthing, check bolt torques, and hand over for electrical work.

An experienced crew of 4–6 people with a small crane typically installs 100–200 kWp of structure per week after the foundations are ready.

Quality and shipping

Corrosion protection, packing and loading

Hot-dip galvanizingTo ISO 1461 / ASTM A123, average zinc thickness about 65–85 µm depending on steel thickness
Zn-Al-Mg coatingZM275 (275 g/m², both sides) for purlins and rails; cut edges self-heal
AluminiumAL6005-T5, anodized or mill finish; stainless steel A2-70 fasteners
InspectionMaterial certificates, coating thickness readings and pre-shipment photos
PackingSteel bundled and strapped with wood spacers; small parts in labelled boxes per bay
LoadingA 40HQ container typically carries the structure for about 250–400 kWp, depending on type and loads
Lead timeUsually 3–5 weeks after drawing approval

Downloads

Catalogue and drawings

PDF
Solar carport catalogueAll product types, standard models and specifications

Layout drawings, typical DWG sections and a structural calculation summary are prepared for your project. Ask for them with your enquiry.

Planning guides: dimensions and spacing · choosing a structure · cost per kW · yield and payback · EV charging design · installation · structural design · FAQ

Questions

Common questions

When should I choose a double column design?

When the site has high design wind speeds, heavy snow, or weak soil, or when the roof needs to be wider than a cantilever can carry economically.

Do the columns get in the way of parking?

The columns sit at the front of the bays, in line with the kerb or wheel stops, so most layouts keep full-size spaces.

What do you need from me for a quotation?

The site location, the number of spaces and a rough layout (a screenshot from Google Maps is enough). If you have them, add the module size, required clear height, and local wind and snow loads.

Do you supply the PV modules and inverters?

We quote the structure as standard. Modules, inverters, EV chargers and batteries can be added to the same shipment on request, or you can use your own brands.

Get a quote

Tell us about your car park

Send the number of spaces and the site location. We reply with a layout, structure proposal and price, usually within one working day.